Engineered floor has problems with timber face layer (7 floor boards, 3mm x 120 mm, total length is about 9 m) . It came off for few floor board most likely because of water. The lamella should be teared off, flattened and glued again or replaced by new one. Perhaps restoration can be done using veneer softener without tearing off lamella/veneer.